ALL DIELECTRIC  SELF-SUPPORTING (ADSS) CABLE          | 
      
      
        Application: 
         The “All Dielectric Self-supporting (ADSS)” cable is designed for aerial self supporting application at short, medium and long span distances. ADSS cable offers a rapid and economical means for deployment by cable television operators, telephone companies and power utilities. It is adopted for high voltage, middle, small span conditions in Power Transmission System or mazy terrain such as river spanning, mountains.
  | 
      
      
        | Description: | 
        Construction: 
          | 
      
      
        The cable consists of 5 to 36 fiber containing tubes or fillers stranded  in up to 3 layers around a central strength member and bound under a PE jacket.  Each tube contains 6 -12 fibers. All the fibers in the cores are  filled with water blocking gel. Fillers may be  used to preserve the cable geometry. A water swelling tape is helically wrapped  around the cable core. Aramid yarns are helically laid to supply peripheral  strengthening of the cable. The outer jacket is tightly bound over the aramid  yarn layer. The cable jacket  incorporates an optional inner polyethylene jacket and an outer  polyethylene or AT (anti-tracking) jacket. When the induction on cable  surface is above 12KV, anti-tracking sheath material (AT) will be applied. With AT outer jacket,  the maximum electric field strength at operating point can reach 35KV. For long span application, a double jacket design can  be considered. An optional ripcord can be put under the jacket layer to  faciliate its removal.   | 
          | 
      
      
      
        Physical Properties:  
          
            
              Span 
                      (m)  | 
              Ice +    Wind:  0mm + 35m/sec  | 
              Ice +    Wind:  12mm + 30m/sec  | 
             
            
              Cable O.D. 
                (mm/in)  | 
              Cable    Weight 
                (kg/km)/(lb/kft)  | 
              Max. Working Tension 
                (N/lb)  | 
              Max. Sag 
                (%)  | 
              Cable O.D. 
                (mm/in)  | 
              Cable    Weight 
                (kg/km)/(lb/kft)  | 
              Max.    Working Tension 
                (N/lb)  | 
              Max. Sag 
                (%)  | 
             
            
              100  | 
              13.9/5.472  | 
              152/102.01  | 
              7578/1704  | 
              2  | 
              13.8/0.543  | 
              150.0/100.67  | 
              6621/1489  | 
              2  | 
             
            
              200  | 
              14.3/0.562  | 
              161/108.05  | 
              10430/2346  | 
              3  | 
              14.1/0.555  | 
              157.0/105.37  | 
              9000/2024  | 
              3  | 
             
            
              400  | 
              15.9/0.625  | 
              199/133.56  | 
              23221/5223  | 
              3  | 
              15.4/0.606  | 
              187.0/125.50  | 
              19255/4331  | 
              3  | 
             
            
              500  | 
              16.7/0.657  | 
              220/147.65  | 
              30590/6881  | 
              3  | 
              16.1/0.633  | 
              204.0/136.91  | 
              24885/5598  | 
              3  | 
             
            
              600  | 
              16.3/0.641  | 
              209/140.27  | 
              26952/6063  | 
              4  | 
              15.7/0.618  | 
              196.0/131.54  | 
              22154/4983  | 
              4  | 
             
            
              800  | 
              16.5/0.649  | 
              216/144.97  | 
              29452/6625  | 
              5  | 
              15.9/0.625  | 
              201.0/134.90  | 
              24042/5408  | 
              6  | 
             
            
              1000  | 
              16.7/0.657  | 
              221/148.32  | 
              31271/7034  | 
              6  | 
              16.1/0.633  | 
              204.0/136.91  | 
              24407/5490  | 
              6  | 
             
           
          * Above table do not cover all of available types. Other ADSS  cables can be manufactured upon customer's  request according to different span and sag environment.             | 
      
      
        Mechanical Properties:  
           
            
              
                Minimum  Bending Radius:  
Under installation:     20×OD 
During operation:      10×OD for unarmoured cables 
20×OD for armoured cables 
Temperature Range: 
Operating Temperature   Range: -40℃(-40℉) to +70℃(+158℉) 
Storage Temperature Range: -50℃(-58℉) to +70℃(+158℉)                  | 
                Maximum Compressive Load:           4000N  
                    Repeated Impact:                                  4.4 N.m (J)  
                    Twist  (Torsion):                 180×10 times, 125×OD 
                    Cyclic Flexing:                  100 cycles . 
                    Crush Resistance:            220N/cm(125lb/in)  | 
               
            | 
      
      
        Fiber Compliance:
  
            
              
                Temperature Cycling 
                    Tensile Strength  
                    Crush  
                    Impact 
                    Repeated Bending 
                    Torsion 
                    Kink 
                    Cable Bend 
                Cool Bend  | 
                IEC60794-1-2-F2                   
                  IEC60794-1-2-E1A 
                  IEC60794-1-2-E3 
                  IEC60794-1-2-E4                   IEC60794-1-2-E6                   
                  IEC60794-1-2-E7                   
                  IEC60794-1-2-E10 
                  IEC60794-1-2-E11                    
                  IEC60794-1-2-E11 | 
               
            | 
      
      
        Safety Compliance: 
         
          
            
              General Purpose  Grade  | 
              Flammability Test: OFN (UL1581) 
                | 
             
            
              Riser Grade  | 
              Flammability Test: OFNR/FT4 (UL1666) 
                | 
             
            
              Plenum Grade  | 
              Flammability Test: OFNP/FT6 (UL 910)  | 
             
            
               FRPVC Grade    | 
              Flammability Test: IEC60332-1  | 
             
            
              LSZH Grade  | 
              Halogen Content Test: IEC 60754-1 
                Acidity Test: IEC 60754;   Smoke Emission Test: IEC61034-1/2                  | 
             
            
              LSFROH Grade       | 
              Halogen Content Test: IEC 60754-1 
                Acidity Test: IEC 60754;   
                Smoke Emission Test: IEC61034-1/2 
                Flammability Test:  IEC60332-1 & IEC 60332-3C/A  | 
             
            
              FR Grade  | 
              Fire  Resistance Test: IEC 60331 / BS 6387  CWZ  | 
             
                     
             | 
      
      
        Standard Compliance: 
         
          Telcordia GR-20                  RUS 7 CFR 1755.900 (REA PE-90)                         ICEA S 87-640                     IEEE 1222  | 
      
      
        Features: 
          
            - High capacity cable offer great flexibility for  placement on overhead transmission towers, eliminating the need for a support  messenger.
 
            - Dry core design and high tension strength  capability suitable for toughest environmental and electrical conditions. 
 
            - Fit for extra high voltage power lines without interruption  of power service to the customers.
 
            - Typical spans with 1%-1.5% installation sag
 
                      |