Central Loose Tube Under Water Cable          | 
      
      
        Application: 
        This  cable exhibits excellent tensile strength and side press retardancy, having  excellent mechanical and environmental performance. Featured  by its thin diameter and light  weight, it is best suited for underwater  condition, junction communication system and long haul communication system. 
  | 
      
      
        | Description: | 
        Construction: 
          | 
      
      
        Central loose tube cable contains one tube  with 2 - 24 fibers,  which is filled with water blocking gel. A  water swelling tape is helically wrapped around the cable core. Either aramid  yarn or fiber glass is wound around the tube to provide physical protection and  tensile strength. The cable is jacketed  with PE for water protection purpose. For direct burial, steel wire armour and corrugated  steel tape armour are applied with an optional PE inner jacket. An optional Aluminium  moisture tape can be incorporated under the jacket for water blocking and  shielding purpose. An optional ripcord can be put under the jacket to  facilitate jacket removal.  | 
          | 
      
      
      
        Physical Properties:  
          
            
              Fiber Count  | 
              Nominal Weight (kg/km)  | 
              Nominal Weight 
               (lb/kft)  | 
              Nominal Outer Diameter 
(mm)  | 
              Nominal Outer Diameter  
                (in)  | 
              Maximum Pulling/Tensile Load   | 
             
            
              Installation  
                (N/lb)  | 
              In Service  
                (N/lb)  | 
             
            
              2-12  | 
              352.0  | 
              236.24  | 
              14.0  | 
              0.553  | 
              8000/1800  | 
              2650/595  | 
             
           
                       | 
      
      
        Mechanical Properties:  
           
            
              
                Minimum Bending Radius:  
Under  installation:     20×OD 
During operation:     10×OD for unarmoured cables;  
20×OD for armoured cables. 
Temperature Range: 
Operating Temperature   Range: -40℃(-40℉) to +70℃(+158℉) 
Storage Temperature   Range: -50℃(-58℉) to +70℃(+158℉)                  | 
                Maximum Compressive Load: 3000N  
                    Repeated Impact:      4.4 N.m (J)  
                    Twist (Torsion):        180×10 times, 125×OD 
                    Cyclic Flexing:         25 cycles for armoured cables.; 
100cycles for unarmoured cables. 
Crush Resistance: 263N/cm(150lb/in)  | 
               
            | 
      
      
        Fiber Compliance:
  
            
              
                Temperature Cycling 
                        Tensile Strength  
                        Crush  
                        Impact 
                        Repeated Bending 
                        Torsion 
                        Kink 
                        Cable Bend 
                        Cool Bend  | 
                IEC60794-1-2-F2 
                  IEC60794-1-2-E1A 
                  IEC60794-1-2-E3 
                  IEC60794-1-2-E4 
                  IEC60794-1-2-E6 
                  IEC60794-1-2-E7 
                  IEC60794-1-2-E10 
                  IEC60794-1-2-E11 
                  IEC60794-1-2-E11 | 
               
            | 
      
      
        Safety Compliance: 
         
          
            
              General Purpose  Grade  | 
              Flammability Test: OFN (UL1581) 
                | 
             
            
              Riser Grade  | 
              Flammability Test: OFNR/FT4 (UL1666) 
                | 
             
            
              Plenum Grade  | 
              Flammability Test: OFNP/FT6 (UL 910)  | 
             
            
               FRPVC Grade    | 
              Flammability Test: IEC60332-1  | 
             
            
              LSZH Grade  | 
              Halogen Content Test: IEC 60754-1 
                Acidity Test: IEC 60754;   Smoke Emission Test: IEC61034-1/2                  | 
             
            
              LSFROH Grade       | 
              Halogen Content Test: IEC 60754-1 
                Acidity Test: IEC 60754;   
                Smoke Emission Test: IEC61034-1/2 
                Flammability Test:  IEC60332-1 & IEC 60332-3C/A  | 
             
            
              FR Grade  | 
              Fire  Resistance Test: IEC 60331 / BS 6387  CWZ  | 
             
                      | 
      
      
        Standard Compliance: 
        Telcordia GR-20                                               RUS 7 CFR 1755.900 (REA PE-90)                                   ICEA S 87-640  | 
      
      
        Features:
  
          
            - Loose tube jelly filled for superior  fiber protection
 
            - Colored coded fibers and binders for  quick and easy identification during installation. 
 
            - High tensile strength design
 
            - Superior mechanical and environmental  performance
 
            - Rugged and lightweight design
 
            - Durable construction to withstand high  water pressure
 
            - Sufficient waterproof to withstand  water penetration
 
                      |