Central Loose Tube Cable          | 
      
      
        Application: 
        This  cable is characterized by light  weight and small diameter, suitable for both aerial and duct installation. The cable  can also be used for direct burial for armoured option.
  | 
      
      
        | Description: | 
          | 
      
      
        Central loose tube cable contains one tube  with 2 - 24 fibers,  which is filled with water blocking gel. Either  aramid yarn or fiber glass is wound around the tube to provide physical  protection and tensile strength. The cable can  be jacketed with either PE or LSZH.  PE is the preferred option in outdoor environment for water protection purpose.   For  direct burial, either steel wire armour or corrugated steel tape armour is applied  with an optional inner jacket of either PVC, PE or LSZH. An Aluminium moisture  tape can be incorporated under the jacket for water blocking and shielding  purpose. A ripcord is located under the jacket to facilitate jacket removal.  | 
        
      
      
        Construction: 
            
          Central Loose Tube_Unarmored  | 
      
      
        Physical Properties:  
          
            
              Fiber Count  | 
              Nominal Weight  
                (kg/km)  | 
              Nominal Weight 
                (lb/kft)  | 
              Nominal Outer Diameter 
(mm)  | 
              Nominal Outer Diameter 
(in)  | 
              Maximum Pulling/Tensile Load  | 
             
            
              Installation  
                (N/lb)  | 
              In Service  
                (N/lb)  | 
             
            
              2-12  | 
              60.0  | 
              40.27  | 
              7.5  | 
              0.296  | 
              1500/337  | 
              445/100  | 
             
            
              14-24  | 
              65.0  | 
              43.62  | 
              8.5  | 
              0.335  | 
              1500/337  | 
              445/100  | 
             
                     
             | 
      
      
        Construction: 
           
  | 
      
      
        Physical Properties: 
          
            
              Fiber    Count  | 
              Nominal    Weight 
                 
               (kg/km)  | 
              Nominal    Weight 
                
                (lb/kft)  | 
              Nominal    Outer Diameter 
(mm)  | 
              Nominal    Outer Diameter  
              (in)  | 
              Maximum Pulling/Tensile Load   | 
             
            
              Installation  
                (N/lb)  | 
              In Service  
                (N/lb)  | 
             
            
              2-12  | 
              125.0  | 
              83.89  | 
              10.5  | 
              0.414  | 
              2670/600  | 
              890/200  | 
             
            
              14-24  | 
              145.0  | 
              97.32  | 
              12.0  | 
              0.473  | 
              2670/600  | 
              890/200  | 
             
            | 
      
      
        Construction: 
           
  | 
      
      
        Physical Properties: 
          
          
            Fiber  
              Count  | 
            Nominal  
              Weight  
              (kg/km)  | 
            Nominal  
              Weight 
              (lb/kft)  | 
            Nominal 
              Outer  
              Diameter 
              (mm)  | 
            Nominal  
              Outer Diameter 
              (in)  | 
            Maximum Pulling/Tensile Load  | 
           
          
            Installation  
              (N/lb)  | 
            In Service 
              (N/lb)  | 
           
          
            2-12  | 
            170.0  | 
            114.09  | 
            10.5  | 
            0.414  | 
            8000/1800  | 
            2650/595  | 
           
          
            14-24  | 
            245.0  | 
            164.43  | 
            12.0  | 
            0.473  | 
            8000/1800  | 
            2650/595  | 
           
          | 
      
      
        Mechanical Properties:  
        
          
          
            Minimum  Bending Radius: 
Under installation:     20×OD 
During operation:     10×OD for unarmoured cables;  
20×OD for armoured cables. 
Temperature Range: 
Operating Temperature   Range: -40℃(-40℉) to +70℃(+158℉) 
Storage Temperature Range: -50℃(-58℉) to +70℃(+158℉)  | 
            Maximum Compressive Load: 3000N  
                Repeated Impact:      4.4 N.m (J)  
                Twist  (Torsion):        180×10 times, 125×OD 
                Cyclic Flexing:         25 cycles for armoured cables; 
100 cycles for unarmoured cables. 
Crush Resistance: 263N/cm (150lb/in)   | 
           
          | 
      
      
        Fiber Compliance:
  
            
              
                Temperature Cycling 
                        Tensile Strength  
                        Crush  
                        Impact 
                        Repeated Bending 
                        Torsion 
                        Kink 
                        Cable Bend 
                        Cool Bend  | 
                IEC60794-1-2-F2 
                  IEC60794-1-2-E1A 
                  IEC60794-1-2-E3 
                  IEC60794-1-2-E4 
                  IEC60794-1-2-E6 
                  IEC60794-1-2-E7 
                  IEC60794-1-2-E10 
                  IEC60794-1-2-E11 
                  IEC60794-1-2-E11 | 
               
            | 
      
      
        Safety Compliance: 
         
          
            
              General Purpose  Grade  | 
              Flammability Test: OFN (UL1581) 
                | 
             
            
              Riser Grade  | 
              Flammability Test: OFNR/FT4 (UL1666) 
                | 
             
            
              Plenum Grade  | 
              Flammability Test: OFNP/FT6 (UL 910)  | 
             
            
               FRPVC Grade    | 
              Flammability Test: IEC60332-1  | 
             
            
              LSZH Grade  | 
              Halogen Content Test: IEC 60754-1 
                Acidity Test: IEC 60754;   Smoke Emission Test: IEC61034-1/2                  | 
             
            
              LSFROH Grade       | 
              Halogen Content Test: IEC 60754-1 
                Acidity Test: IEC 60754;   
                Smoke Emission Test: IEC61034-1/2 
                Flammability Test:  IEC60332-1 & IEC 60332-3C/A  | 
             
            
              FR Grade  | 
              Fire  Resistance Test: IEC 60331 / BS 6387  CWZ  | 
             
                     
             | 
      
      
        Standard Compliance: 
        Telcordia GR-20                                     RUS 7 CFR 1755.900 (REA PE-90)                         ICEA S 87-640  | 
      
      
        Features:
  
            
              - Loose Tube construction  provides environmental protection
 
              - Loose tube jelly filled for superior  fiber protection
 
              - Colored coded fibers and binders for  quick and easy identification during installation
 
              - Very lightweight and flexible design  allows for easy installation
 
              - UV or moisture resistant for outdoor  application
 
              - Compact design with small cable  diameter
 
              - All Dielectric strength member
 
              - Anti-termite and rodent protection as  options
 
              - Optional aluminium moisture  barrier for EMI protection
 
                          |