Multi Loose Tube Under Water Cable          | 
      
      
        Application: 
        This  cable exhibits excellent tensile strength and side press retardancy, having  excellent mechanical and environmental performance. Featured by its thin  diameter and light weight, it  is best suited for underwater condition, junction communication system and long haul communication system.
  | 
      
      
        | Description: | 
        Construction: 
          | 
      
      
        The cable consists of 5 to 36 fiber containing tubes  or fillers stranded in up to 3 layers around a central strength member and  bound under a PE jacket. Each tube contains 4 -12 fibers. Solid or stranded steel  coated with polyethylene is usually used as central strength member. Fiber glass reinforced  plastics (FRP) will be used as central strength member if non metallic  construction is required. Either aramid yarn or fiber glass is wound around the  tube to provide physical protection and tensile strength. The cable incorporates the first layer  of PE inner jacket, a layer of corrugated steel tape armour, the second layer  of PE inner jacket, a layer of steel wire armour and PE outer jacket. An  optional Aluminium moisture tape can be incorporated under the jacket for water  blocking and shielding purpose. An optional ripcord is located under the jacket  to facilitate jacket removal.  | 
          | 
      
      
      
        Physical Properties:  
          
            
              Fiber Count  | 
              Nominal Weight  
                (kg/km)  | 
              Nominal Weight  
                (lb/kft)  | 
              Nominal Outer Diameter 
(mm)  | 
              Nominal Outer Diameter 
(in)  | 
              Maximum Pulling/Tensile Load   | 
             
            
              Installation  
                (N/lb)  | 
              In Service  
                (N/lb)  | 
             
            
              2-24  | 
              650.0  | 
              436.24  | 
              20.3  | 
              0.798  | 
              8000/1800  | 
              2650/595  | 
             
            
              26-36  | 
              716.0  | 
              480.54  | 
              21.6  | 
              0.849  | 
              8000/1800  | 
              2650/595  | 
             
            
              38-72  | 
              1008.0  | 
              676.51  | 
              25.2  | 
              0.991  | 
              8000/1800  | 
              2650/595  | 
             
            | 
      
      
        Mechanical Properties:  
           
            
              
                Minimum Bending Radius: 
Under  installation:    20×OD 
During operation:     10×OD for unarmoured cables;  
20×OD for armoured cables. 
Temperature Range: 
Operating Temperature   Range: -40℃(-40℉) to +70℃(+158℉) 
Storage Temperature   Range: -50℃(-58℉) to +70℃(+158℉)                  | 
                Maximum Compressive Load: 4000N for unarmoured cables;  
                               6000N for armoured cables 
Repeated Impact:       4.4 N.m (J)  
Twist (Torsion):         180×10 times, 125×OD 
Cyclic Flexing:          25 cycles for armoured cables.; 
100 cycles for unarmoured cables. 
Crush Resistance:   220N/cm(125lb/in)  | 
               
            | 
      
      
        Fiber Compliance:
  
            
              
                Temperature Cycling 
                        Tensile Strength  
                        Crush  
                        Impact 
                        Repeated Bending 
                        Torsion 
                        Kink 
                        Cable Bend 
                        Cool Bend  | 
                IEC60794-1-2-F2 
                  IEC60794-1-2-E1A 
                  IEC60794-1-2-E3 
                  IEC60794-1-2-E4 
                  IEC60794-1-2-E6 
                  IEC60794-1-2-E7 
                  IEC60794-1-2-E10 
                  IEC60794-1-2-E11 
                  IEC60794-1-2-E11 | 
               
            | 
      
      
        Safety Compliance: 
         
          
            
              General Purpose  Grade  | 
              Flammability Test: OFN (UL1581) 
                | 
             
            
              Riser Grade  | 
              Flammability Test: OFNR/FT4 (UL1666) 
                | 
             
            
              Plenum Grade  | 
              Flammability Test: OFNP/FT6 (UL 910)  | 
             
            
               FRPVC Grade    | 
              Flammability Test: IEC60332-1  | 
             
            
              LSZH Grade  | 
              Halogen Content Test: IEC 60754-1 
                Acidity Test: IEC 60754;   Smoke Emission Test: IEC61034-1/2                  | 
             
            
              LSFROH Grade       | 
              Halogen Content Test: IEC 60754-1 
                Acidity Test: IEC 60754;   
                Smoke Emission Test: IEC61034-1/2 
                Flammability Test:  IEC60332-1 & IEC 60332-3C/A  | 
             
            
              FR Grade  | 
              Fire  Resistance Test: IEC 60331 / BS 6387  CWZ  | 
             
                      | 
      
      
        Standard Compliance: 
        Telcordia GR-20                                              RUS 7 CFR 1755.900 (REA PE-90)                          ICEA S 87-640   | 
      
      
        Features:
  
          
            - Loose tube jelly filled for superior fiber       protection
 
            - Colored coded fibers and binders for quick and       easy identification during installation. 
 
            - High tensile strength design
 
            - Superior mechanical and environmental       performance
 
            - Rugged and lightweight design
 
            - Durable construction to withstand high water       pressure
 
            - Sufficient waterproof to withstand water       penetration
 
            |