Military Cable  

Military Cable

M81381/17

Application and Description:

These FEP/polyimide/FEP tape insulated single-core M81381/17 cables are used in aerospace applications and other challenging applications. It is well-suited to applications concerned with smoke emission and overload stability.

Construction:

Conductor: Stranded silver-plated copper conductor

Insulation: FEP/polyimide/FEP tape insulation

Insulation Wall Thickness: 0.0065”

Jacket: modified aromatic polyimide coating

Characteristics:

Temperature Range: -55°C + 200°C

Voltage Rating: 600 volts

Color Code: MIL-STD-104 (See page 42 )

10 basic colors(BLK,BRN,RED,ORN,YEL,GRN,BLU,VIO,GRY,WHT)

Dimensions and Weight:

AWG Size

Conductor Stranding

Conductor Diam.

Max.

Conductor Diam.

Min.

Max. O.D.

Min. O.D.

Maximum Resistance (Ohm/1000' @ 20°C)

Approx LBS/MFT

 

 

in

mm

in

mm

in

mm

in

mm

   

26

19/38

0.019

0.480

0.018

0.460

0.03

0.762

0.028

0.700

38.40

1.2

24

19/36

0.024

0.610

0.023

0.580

0.035

0.889

0.032

0.800

24.30

1.8

22

19/34

0.030

0.760

0.029

0.740

0.041

1.041

0.038

1.000

15.10

2.6

20

19/32

0.038

0.970

0.037

0.940

0.049

1.245

0.046

1.200

9.19

4.1

18

19/30

0.048

1.220

0.046

1.170

0.058

1.473

0.055

1.400

5.79

6.3

16

19/29

0.054

1.370

0.052

1.320

0.065

1.651

0.062

1.600

4.52

7.9

14

19/27

0.068

1.730

0.065

1.650

0.078

1.981

0.075

1.900

2.88

12.3

12

37/28

0.087

2.210

0.084

2.130

0.098

2.489

0.094

2.400

1.90

19