| Railway Cables | ||||||||||||
K13 PVC Subway Signalling Cables for
                        Metro/Local Trains/Tramlines

Application
The cables are designed for remote control and teletransmission in underground railway networks. The cables can be laid in channel, cable tray, or on hook supports, along suburban railway lines electrifi ed at maximum 1500V DC
Standards
● AFNOR NF F 55-633
Construction
Conductors
                          Solid copper conductor, 0.6/0.8/1.0/1.2 mm nominal diameter.
Insulation
                          Polyethylene insulation.
Cabling Element
                          Pair/Quad.
Stranding
                          4-pair cables are composed of pairs, while other cables are composed of star quads.
Spare Pairs
Spare pairs may be provided according to capacity of cables.
Core Wrapping
                            One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap.
Screen
                            Aluminium/Nylon tape bonded with a special PVC sealing sheath or Aluminium/PE tape bonded with a
                          halogen-free fi re-retardant sheath.
Drain Wire
A tinned copper drain wire, 0.5mm nominal diameter.
Bedding
                          Several glass silk tapes are helically laid with an overlap to form bedding.
Armour
Two helically applied steel tapes.
Outer Sheath
LSPVC.
Electrical Characteristics at 20℃
| Nominal Conductor Diameter | mm  | 
                              0.6  | 
                              0.8  | 
                              1.0  | 
                              1.2  | 
                            
| Nominal Mutual Capacity | nF/km  | 
                              57.5  | 
                              57.5  | 
                              57.5  | 
                              57.5  | 
                            
| Minimum Insulation Resistance | MΩ.km  | 
                              5000  | 
                              5000  | 
                              5000  | 
                              5000  | 
                            
| Maximum Operating Voltage | V  | 
                              200  | 
                              400  | 
                              500  | 
                              750  | 
                            
| Maximum Permissible Current | A  | 
                              0.35  | 
                              0.63  | 
                              1.0  | 
                              1.4  | 
                            
Mechanical and Thermal Properties
 Minimum Bending Radius: 8×OD (static); 16×OD (dynamic)
                             Temperature Range: -40℃ to +60℃ (during operation); -20℃ to +50℃ (during installation)
Core Identification
4-pair cable:
                            Pair1: black/colourless Pair2: blue/ colourless
                            Pair3: yellow/colourless Pair4: red/ colourless
                            Other cable:
                            Side circuit 1 of a quad a-wire: sequence of black/blue/yellow/red/green/blue/yellow, etc.
                            b-wire: colourless
                            Side circuit 2 of a quad a-wire: grey
                          b-wire: white
Unit binder: sequence of white/blue/yellow/brown/black/red/green/violet
Dimensions And Weight
Cable Code  | 
                              Number of Pairs  | 
                              Nominal Sheath Thickness mm  | 
                              Nominal Overall Diameter mm  | 
                              Nominal Weight kg/km  | 
                            |
Inner  | 
                              Outer  | 
                            ||||
0.6mm Conductor, 0.96mm Insulated Wire  | 
                            |||||
RS/K13-2Y(L)2YBY-4P0.6  | 
                              4  | 
                              1.0  | 
                              1.0  | 
                              12.5  | 
                              220  | 
                            
RS/K13-2Y(L)2YBY-8P0.6  | 
                              8(4Q)  | 
                              1.0  | 
                              1.0  | 
                              13.5  | 
                              260  | 
                            
RS/K13-2Y(L)2YBY-14P0.6  | 
                              14(7Q)  | 
                              1.0  | 
                              1.2  | 
                              15.5  | 
                              350  | 
                            
RS/K13-2Y(L)2YBY-28P0.6  | 
                              28(14Q)  | 
                              1.0  | 
                              1.4  | 
                              17.5  | 
                              480  | 
                            
RS/K13-2Y(L)2YBY-56P0.6  | 
                              56(4 x 7Q)  | 
                              1.0  | 
                              1.4  | 
                              22.0  | 
                              750  | 
                            
0.8mm Conductor, 1.27mm Insulated Wire  | 
                            |||||
RS/K13-2Y(L)2YBY-4P0.8  | 
                              4  | 
                              1.0  | 
                              1.0  | 
                              14.0  | 
                              280  | 
                            
RS/K13-2Y(L)2YBY-8P0.8  | 
                              8(4Q)  | 
                              1.0  | 
                              1.2  | 
                              15.0  | 
                              340  | 
                            
RS/K13-2Y(L)2YBY-14P0.8  | 
                              14(7Q)  | 
                              1.0  | 
                              1.4  | 
                              18.0  | 
                              470  | 
                            
RS/K13-2Y(L)2YBY-28P0.8  | 
                              28(14Q)  | 
                              1.0  | 
                              1.4  | 
                              21.0  | 
                              700  | 
                            
RS/K13-2Y(L)2YBY-56P0.8  | 
                              56(4 x 7Q)  | 
                              1.0  | 
                              1.6  | 
                              28.5  | 
                              1200  | 
                            
1.0mm Conductor, 1.8mm Insulated Wire  | 
                            |||||
RS/K13-2Y(L)2YBY-4P1  | 
                              4  | 
                              1.0  | 
                              1.2  | 
                              15.5  | 
                              340  | 
                            
RS/K13-2Y(L)2YBY-8P1  | 
                              8(4Q)  | 
                              1.0  | 
                              1.4  | 
                              17.5  | 
                              460  | 
                            
RS/K13-2Y(L)2YBY-14P1  | 
                              14(7Q)  | 
                              1.0  | 
                              1.4  | 
                              20.5  | 
                              630  | 
                            
RS/K13-2Y(L)2YBY-28P1  | 
                              28(14Q)  | 
                              1.0  | 
                              1.6  | 
                              25.0  | 
                              990  | 
                            
RS/K13-2Y(L)2YBY-56P1  | 
                              56(4 x 7Q)  | 
                              1.0  | 
                              1.8  | 
                              34.0  | 
                              1700  | 
                            
1.2mm Conductor, 2.0mm Insulated Wire  | 
                            |||||
RS/K13-2Y(L)2YBY-2P1.2  | 
                              2(1Q)  | 
                              1.0  | 
                              1.2  | 
                              12.5  | 
                              240  | 
                            
RS/K13-2Y(L)2YBY-4P1.2  | 
                              4  | 
                              1.0  | 
                              1.4  | 
                              17.0  | 
                              420  | 
                            
RS/K13-2Y(L)2YBY-8P1.2  | 
                              8(4Q)  | 
                              1.0  | 
                              1.4  | 
                              18.5  | 
                              530  | 
                            
RS/K13-2Y(L)2YBY-14P1.2  | 
                              14(7Q)  | 
                              1.0  | 
                              1.4  | 
                              21.5  | 
                              740  | 
                            
RS/K13-2Y(L)2YBY-28P1.2  | 
                              28(14Q)  | 
                              1.0  | 
                              1.6  | 
                              27.5  | 