Rolling Stock Cables | |||||||||||||||
|
Rolling Stock Cables
EN 50306 Thin Wall Instrumentation & Control Cable
FIREROL FRL-TW-05SU
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound
Electrical & Mechanical Properties
Nominal Voltage | 300/500 V |
Maximum Conductor Temperature | +120/+150 deg (fixed installation) |
Minimum Permissible Ambient Temperature | -25/-40 deg (fixed installation) |
Bending Radius | 3 x Overall Diameter |
Chemical & Environmental Properties
EN 60684-2 | No fluorine |
EN 50305; EN 60811-2-1 | Resistance to mineral oil & fuel oil, acid & alkali |
EN 50305 | Resistance to ozone |
Fire Performance for rolling stock application
EN 50306-2 | Hazard levels HL1, HL2/HL3, HL4 |
DIN 5510-2 | Protection level 1/2/3/4 |
BS 6853 | Interior use 1a, 1b, II; Exterior use 1a, 1b, II |
NF F 16-101 | F0 |
Fire Performance in general
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 |
Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 |
Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 | Low Toxicity |
NFF 16101; NFF 63808; BS6853 | Smoke index |
FRL-TW-05SU 300/500 V
Nominal |
Number X Nominal Diameter of Wire |
Diameter |
Min. Mean |
Overall Diameter |
Weight |
Conductor Resistance |
||
mm2 |
n x mm |
Min. |
Max. |
Min. |
Max. |
20°C |
||
mm |
mm |
mm |
mm |
mm |
kg/km |
mm |
||
0.5 |
19 x 0.18 | 0.80 |
0.95 |
0.18 |
1.15 |
1.45 |
7 |
40.1 |
0.75 |
37 x 0.16(a) | 1.00 |
1.15 |
0.18 |
1.35 |
1.65 |
8 |
26.7 |
1.0 |
37 x 0.18(a) | 1.10 |
1.30 |
0.18 |
1.45 |
1.80 |
10 |
20.0 |
1.5 |
37 x 0.23(a) | 1.45 |
1.65 |
0.22 |
1.95 |
2.30 |
20 |
13.7 |
2.5 |
37 x 0.30(a) | 1.85 |
2.15 |
0.28 |
2.50 |
2.85 |
25 |
8.21 |
(a) =This cable may be supplied in 19 strand conductor providing all product performance requirements in the specification are met