Rolling Stock Cables | |||||||||||||||
|
Chinese Standard Rolling Stock Cables
Non-halogen Flame-retardant Electromagnetic Shield Power Cables
WD-PWYYRP-125 1.8/3 kV
Application :
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where
handling and installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction :
Conductor
Soft tinned annealed brass wires
Insulation
125°C non-halogen flame-retardant compound
Screen
Tinned copper wire braid
Sheath
125°C non-halogen flame-retardant compound.
|
A. Conductor B. Insulation C. Screen D.Sheath |
Electrical & Mechanical Properties :
Nominal Voltage | 1.8/3 kV |
Long-term Working Temperature | 125°C |
Short Circuit Temperature (5s) | 250°C |
Long-term Working Ambient Temperature | -40°C/+70°C |
Minimum Bending Radius | 5 x Overall Diameter |
Fire Performance :
Flame Retardant | GB 12666.2-1990 DZ-1 |
Low Corrosivity (Acidity & Conductivity) | GB/T17650.1-1998; GB/T17650.2-1998 |
Halogen Free | GB/T17650.1-1998; GB/T17650.2-1998 |
Low Smoke | GB/T17650.1-1998; GB/T17650.2-1998 |
WD-PWYYRP-125 1.8/3 kV:
Nominal Cross-Sectional Area |
Stranding | Insulation Thickness | Sheath Thickness | Maximum Overall Diameter | Weight | Maximum Conductor Resistance 20°C |
mm² | No/mm | mm | mm | mm | kg/km | Ω/km |
35 | 1107/0.2 | 1.8 | 1.2 | 16.5 | 666 | 0.393 |
70 | 2220/0.2 | 1.9 | 1.5 | 21.0 | 1172 | 0.210 |