Rolling Stock Cables
EN 50264 EN 50306 EN 50382 Databus Cables NF F 63-826 NF F 63-808 NF F 63-827 RSE/STD/024 PART 6

 Chinese Standard Rolling Stock Cables

Silicon Rubber Cables
YGC-KBR 1.5 kV

Application :

-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction :

Conductor
Tinned annealed copper wires
Insulation
High tear strength silicon rubber

 YGC-KBR 1.5 kV

A. Conductor                                      B. Insulation

Electrical & Mechanical Properties :

Nominal Voltage 1.5 kV
Long-term Working Temperature 150°C
Short Circuit Temperature (5s) 300°C
Long-term Working Ambient Temperature -50°C/+150°C
Minimum Bending Radius 3 x Overall Diameter

Fire Performance :

Flame Retardant GB/T18380.1-2001 DZ-1
Low Corrosivity (Acidity & Conductivity) GB/T17650.1-1998; GB/T17650.2-1998
Halogen Free GB/T17650.1-1998; GB/T17650.2-1998
Low Smoke GB/T17650.1-1998; GB/T17650.2-1998

YGC-KBR 1.5 kV:

Nominal
Cross-Sectional Area
Stranding Insulation Thickness Maximum Overall Diameter Weight Maximum Conductor
Resistance 20°C
mm² No/mm mm mm kg/km Ω/km
50 999/0.25 3.5 18.5 911 0.393
95 1936/0.25 3.5 22.5 1485 0.210