JIS Shipboard Cables 

0.6/1kV

[FA-] SPYCS, SPYCBS, DPYCS, TPYCS, FPYCS
[FA-] SPYCYS, SPYCBYS, DPYCYS, TPYCYS, FPYCYS

JIS Shipboard Cables

STANDARDS
JISC 3410-1999
IEC 60332-1
IEC 60332-3 Cat.A(for FA-type)

CABLE CONSTRUCTION

Conductor

S(D,T)

Tinned annealed stranded copper, class 2 according to IEC 60228

Insulation

P

85°C EPR as per JIS C 3401

Cabling

 

Insulated conductors shall be cabled.
Flame retardant & non-hygroscopic fillers may be used

Overall Shield

S

Tinned copper wire braid

Bedding

Y

PVC as per JIS C 3401

Armor

C
(CB)

Galvanized steel wire braid(-C TYPE) or
copper alloy wire braid(-CB TYPE)

Sheath

Y

PVC as per JIS C 3401

Core identification

 

1C Black
2C Black, White
3C Black, White, Red

Outer sheath color

 

Black

Cable Parameter

0.6/1KV (FA-) SPYCS, SPYCBS

Conductor

Thick. of insul- ation

Dia. of shield wire

Thick. of bedding

Dia. over bedding

Dia. of armor wire

(FA-) SPYCS, SPYCBS

Size

Construction

O.D

Nom.
overall dia.

Tolerance

Cable weight

mm²

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

Kg / Km

1.5

7/0.53

1.59

1

0.12

1

6.4

0.3

8

0.4

110

2.5

7/0.67

2.01

1

0.12

1

6.9

0.3

8.5

0.4

130

4

7/0.85

2.55

1

0.12

1

7.5

0.3

9.1

0.5

150

6

7/1.04

3.12

1

0.14

1

8.1

0.3

9.7

0.5

180

10

7/1.35

4.05

1

0.14

1.1

9.4

0.3

11

0.6

240

16

7/1.70

5.1

1

0.14

1.1

10.4

0.3

12

0.6

320

25

7/2.14

6.42

1.2

0.14

1.2

12.3

0.3

13.9

0.7

450

35

7/2.52

7.56

1.2

0.16

1.2

13.6

0.3

15.2

0.8

550

50

19/1.78

8.9

1.4

0.16

1.3

15.7

0.3

17.3

0.9

710

70

19/2.14

10.7

1.6

0.16

1.4

18.1

0.3

19.7

1

980

95

19/2.52

12.6

1.6

0.16

1.5

20.3

0.3

21.9

1.1

1280

120

37/2.03

14.2

1.6

0.18

1.6

22.2

0.3

23.8

1.2

1570

150

37/2.25

15.8

1.8

0.18

1.6

24.2

0.3

25.8

1.3

1900

185

37/2.52

17.6

2

0.18

1.7

26.6

0.3

28.2

1.4

2310

240

61/2.25

20.3

2.2

0.2

1.8

30.1

0.4

32.2

1.6

2980

300

61/2.52

22.7

2.4

0.2

2

33.4

0.4

35.5

1.8

3750

0.6/1KV (FA-) SPYCYS, SPYCBYS

Conductor

Thick. of insulation

Dia. of shield wire

Thick. of bedding

Dia. over bedding

Dia. of armor wire

Thick. of covering

(FA-) SPYCYS, SPYCBYS

Size

Construction

O.D

Nom.
overall dia.

Tolerance

Cable weight

mm²

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

Kg / Km

1.5

7/0.53

1.59

1

0.12

1

6.4

0.3

0.8

9.9

0.5

150

2.5

7/0.67

2.01

1

0.12

1

6.9

0.3

0.8

10.6

0.5

160

4

7/0.85

2.55

1

0.12

1

7.5

0.3

0.8

11.2

0.6

185

6

7/1.04

3.12

1

0.14

1

8.1

0.3

0.8

12.1

0.6

220

10

7/1.35

4.05

1

0.14

1.1

9.4

0.3

0.9

13.4

0.7

280

16

7/1.70

5.1

1

0.14

1.1

10.4

0.3

0.9

14.6

0.7

370

25

7/2.14

6.42

1.2

0.14

1.2

12.3

0.3

0.9

16.5

0.8

500

35

7/2.52

7.56

1.2

0.16

1.2

13.6

0.3

1

18

0.9

620

50

19/1.78

8.9

1.4

0.16

1.3

15.7

0.3

1

20.3

1

790

70

19/2.14

10.7

1.6

0.16

1.4

18.1

0.3

1.1

22.9

1.1

1100

95

19/2.52

12.6

1.6

0.16

1.5

20.3

0.3

1.1

21.9

1.1

1400

120

37/2.03

14.2

1.6

0.18

1.6

22.2

0.3

1.2

23.8

1.2

1700

150

37/2.25

15.8

1.8

0.18

1.6

24.2

0.3

1.2

25.8

1.3

2020

185

37/2.52

17.6

2

0.18

1.7

26.6

0.3

1.3

28.2

1.4

2500

240

61/2.25

20.3

2.2

0.2

1.8

30.1

0.4

1.4

32.2

1.6

3200

300

61/2.52

22.7

2.4

0.2

2

33.4

0.4

1.5

35.5

1.8

4000

0.6/1KV (FA-) DPYCS

Conductor

Thick. of insulation

Dia. of shield wire

Thick. of bedding

Dia. over bedding

Dia. of steel wire

(FA-) DPYCS

Size

Construction

O.D

Nom.
overall dia.

Tolerance

Cable weight

mm²

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

Kg / Km

1.5

7/0.53

1.59

1.0

0.14

1.2

11.3

0.3

12.6

0.5

265

2.5

7/0.67

2.01

1.0

0.14

1.2

12.2

0.3

13.5

0.5

310

4

7/0.85

2.55

1.0

0.16

1.2

13.4

0.3

14.7

0.6

380

6

7/1.04

3.12

1.0

0.16

1.3

14.4

0.3

15.9

0.8

460

10

7/1.35

4.05

1.0

0.16

1.3

16.4

0.3

18.0

0.9

610

16

7/1.70

5.1

1.0

0.16

1.4

18.7

0.3

20.2

1.0

790

25

7/2.14

6.42

1.2

0.18

1.6

22.5

0.3

24.1

1.2

1100

35

7/2.52

7.56

1.2

0.18

1.7

25.0

0.3

26.6

1.3

1400

50

19/1.78

8.9

1.4

0.18

1.8

29.1

0.3

30.6

1.5

1800

70

19/2.14

10.7

1.6

0.2

2.0

34.0

0.4

36.1

1.8

2640

95

19/2.52

12.6

1.6

0.26

2.2

38.7

0.4

40.7

2.0

3410

120

37/2.03

14.2

1.6

0.26

2.3

42.1

0.4

44.2

2.2

3900

150

37/2.25

15.8

1.8

0.18

1.6

24.2

0.3

25.8

1.3

1900

185

37/2.52

17.6

2

0.18

1.7

26.6

0.3

28.2

1.4

2310

240

61/2.25

20.3

2.2

0.2

1.8

30.1

0.4

32.2

1.6

2980

300

61/2.52

22.7

2.4

0.2

2

33.4

0.4

35.5

1.8

3750

0.6/1KV (FA-) DPYCYS

Conductor

Thick. of insulation

Dia. of shield wire

Thick. of bedding

Dia. over bedding

Dia. of steel wire

Thick. of covering

(FA-) DPYCYS

Size

Construction

O.D

Nom.
overall dia.

Tolerance

Cable weight

mm²

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

Kg / Km

1.5

7/0.53

1.59

1.0

0.14

1.2

11.3

0.3

0.9

14.6

0.6

325

2.5

7/0.67

2.01

1.0

0.14

1.2

12.2

0.3

0.9

15.5

0.6

375

4

7/0.85

2.55

1.0

0.16

1.2

13.4

0.3

1.0

16.9

0.7

455

6

7/1.04

3.12

1.0

0.16

1.3

14.4

0.3

1.0

18.1

0.9

550

10

7/1.35

4.05

1.0

0.16

1.3

16.4

0.3

1.0

20.2

1.0

710

16

7/1.70

5.1

1.0

0.16

1.4

18.7

0.3

1.1

22.6

1.1

910

25

7/2.14

6.42

1.2

0.18

1.6

22.5

0.3

1.2

26.7

1.3

1290

35

7/2.52

7.56

1.2

0.18

1.7

25.0

0.3

1.3

29.3

1.5

1620

50

19/1.78

8.9

1.4

0.18

1.8

29.1

0.3

1.4

33.6

1.7

2030

70

19/2.14

10.7

1.6

0.2

2.0

34.0

0.4

1.5

39.3

2.0

2900

95

19/2.52

12.6

1.6

0.26

2.2

38.7

0.4

1.6

44.2

2.2

3700

120

37/2.03

14.2

1.6

0.26

2.3

42.1

0.4

1.7

47.9

2.4

4320

150

37/2.25

15.8

1.8

0.18

1.6

24.2

0.3

1.2

25.8

1.3

2020

185

37/2.52

17.6

2

0.18

1.7

26.6

0.3

1.3

28.2

1.4

2500

240

61/2.25

20.3

2.2

0.2

1.8

30.1

0.4

1.4

32.2

1.6

3200

300

61/2.52

22.7

2.4

0.2

2

33.4

0.4

1.5

35.5

1.8

4000

0.6/1KV (FA-) TPYCS

Conductor

Thick. of insulation

Dia. of shield wire

Thick. of bedding

Dia. over bedding

Dia. of steel wire

(FA-) TPYCS

Size

Construction

O.D

Nom.
overall dia.

Tolerance

Cable weight

mm²

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

Kg / Km

1.5

7/0.53

1.59

1.0

0.14

1.2

11.9

0.3

13.2

0.5

305

2.5

7/0.67

2.01

1.0

0.14

1.2

12.9

0.3

14.2

0.6

360

4

7/0.85

2.55

1.0

0.16

1.3

14.4

0.3

15.7

0.6

455

6

7/1.04

3.12

1.0

0.16

1.3

15.3

0.3

16.8

0.8

530

10

7/1.35

4.05

1.0

0.16

1.4

17.5

0.3

19.0

1.0

730

16

7/1.70

5.1

1.0

0.16

1.5

19.8

0.3

21.4

1.1

990

25

7/2.14

6.42

1.2

0.18

1.6

24.0

0.3

25.6

1.3

1400

35

7/2.52

7.56

1.2

0.18

1.7

26.7

0.3

28.2

1.4

1850

50

19/1.78

8.9

1.4

0.2

1.9

31.1

0.3

32.7

1.6

2450

70

19/2.14

10.7

1.6

0.26

2.1

36.6

0.4

38.7

1.9

3350

95

19/2.52

12.6

1.6

0.26

2.3

41.3

0.4

43.4

2.2

4390

120

37/2.03

14.2

1.6

0.26

2.4

45.0

0.4

47.1

2.4

5350

150

37/2.25

15.8

1.8

0.26

2.6

49.8

0.4

51.8

2.6

6100

185

37/2.52

17.6

2.0

0.26

2.8

54.9

0.4

57.0

2.9

7530

0.6/1KV (FA-) TPYCYS

Conductor

Thick. of insulation

Dia. of shield wire

Thick. of bedding

Dia. over bedding

Dia. of steel wire

Thick. of covering

(FA-) TPYCYS

Size

Construction

O.D

Nom.
overall dia.

Tolerance

Cable weight

mm²

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

Kg / Km

1.5

7/0.53

1.59

1.0

0.14

1.2

11.9

0.3

0.9

15.2

0.6

365

2.5

7/0.67

2.01

1.0

0.14

1.2

12.9

0.3

1.0

16.4

0.7

430

4

7/0.85

2.55

1.0

0.16

1.3

14.4

0.3

1.0

17.9

0.7

535

6

7/1.04

3.12

1.0

0.16

1.3

15.3

0.3

1.0

18.9

1.0

610

10

7/1.35

4.05

1.0

0.16

1.4

17.5

0.3

1.1

21.4

1.1

830

16

7/1.70

5.1

1.0

0.16

1.5

19.8

0.3

1.1

23.8

1.2

1100

25

7/2.14

6.42

1.2

0.18

1.6

24.0

0.3

1.2

28.2

1.4

1550

35

7/2.52

7.56

1.2

0.18

1.7

26.7

0.3

1.3

31.0

1.6

2020

50

19/1.78

8.9

1.4

0.2

1.9

31.1

0.3

1.4

35.7

1.8

2670

70

19/2.14

10.7

1.6

0.26

2.1

36.6

0.4

1.6

42.1

2.1

3650

95

19/2.52

12.6

1.6

0.26

2.3

41.3

0.4

1.7

47.0

2.3

4730

120

37/2.03

14.2

1.6

0.26

2.4

45.0

0.4

1.8

50.9

2.5

5740

150

37/2.25

15.8

1.8

0.26

2.6

49.8

0.4

1.9

55.9

2.8

6570

185

37/2.52

17.6

2.0

0.26

2.8

54.9

0.4

2.0

61.3

3.1

8080

0.6/1KV (FA-) FPYCS

Conductor

Thick. of insulation

Dia. of shield wire

Thick. of bedding

Dia. over bedding

Dia. of steel wire

(FA-) FPYCS

Size

Construction

O.D

Nom.
overall dia.

Tolerance

Cable weight

mm²

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

Kg / Km

1.5

7/0.53

1.59

1.0

0.14

1.2

12.4

0.3

14.0

0.7

400

2.5

7/0.67

2.01

1.0

0.16

1.2

13.7

0.3

15.3

0.8

480

4

7/0.85

2.55

1.0

0.16

1.3

15.1

0.3

16.7

0.8

600

6

7/1.04

3.12

1.0

0.16

1.4

16.7

0.3

18.3

0.9

740

10

7/1.35

4.05

1.0

0.16

1.4

19.1

0.3

20.7

1.0

1030

16

7/1.70

5.1

1.0

0.18

1.5

22.0

0.3

23.6

1.2

1350

25

7/2.14

6.42

1.2

0.18

1.7

26.5

0.3

28.1

1.4

1950

35

7/2.52

7.56

1.2

0.18

1.8

29.5

0.3

31.1

1.6

2540

50

19/1.78

8.9

1.4

0.20

2.0

34.5

0.4

36.6

1.8

3480

70

19/2.14

10.7

1.4

0.26

2.2

39.5

0.4

41.6

2.1

4750

95

19/2.52

12.6

1.6

0.26

2.4

45.9

0.4

48.0

2.4

6280

120

37/2.03

14.2

1.6

0.26

2.6

50.1

0.4

52.1

2.6

7590

150

37/2.25

15.8

1.8

0.26

2.8

55.3

0.4

57.4

2.9

9150

185

37/2.52

17.6

2.0

0.26

3.0

61.2

0.4

63.2

3.2

11150

0.6/1KV (FA-) FPYCYS

Conductor

Thick. of insulation

Dia. of shield wire

Thick. of bedding

Dia. over bedding

Dia. of steel wire

Thick. of covering

(FA-) TPYCYS

Size

Construction

O.D

Nom.
overall dia.

Tolerance

Cable weight

mm²

No./mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

Kg / Km

1.5

7/0.53

1.59

1.0

0.14

1.2

12.4

0.3

1.0

16.0

0.8

490

2.5

7/0.67

2.01

1.0

0.16

1.2

13.7

0.3

1.0

17.4

0.9

580

4

7/0.85

2.55

1.0

0.16

1.3

15.1

0.3

1.0

18.9

0.9

720

6

7/1.04

3.12

1.0

0.16

1.4

16.7

0.3

1.1

20.5

1.0

880

10

7/1.35

4.05

1.0

0.16

1.4

19.1

0.3

1.1

23.1

1.2

1190

16

7/1.70

5.1

1.0

0.18

1.5

22.0

0.3

1.2

26.1

1.3

1550

25

7/2.14

6.42

1.2

0.18

1.7

26.5

0.3

1.3

30.9

1.5

2200

35

7/2.52

7.56

1.2

0.18

1.8

29.5

0.3

1.4

34.0

1.7

2780

50

19/1.78

8.9

1.4

0.20

2.0

34.5

0.4

1.5

39.8

2.0

3750

70

19/2.14

10.7

1.4

0.26

2.2

39.5

0.4

1.6

45.1

2.3

5280

95

19/2.52

12.6

1.6

0.26

2.4

45.9

0.4

1.8

51.8

2.6

6750

120

37/2.03

14.2

1.6

0.26

2.6

50.1

0.4

1.9

56.2

2.8

8150

150

37/2.25

15.8

1.8

0.26

2.8

55.3

0.4

2.0

61.8

3.1

1210

185

37/2.52

17.6

2.0

0.26

3.0

61.2

0.4

2.2

67.9

3.4

11980