Automotive Cable | |||
Germany Standard | Japanese Standard | American Standard | more |
Automotive Cable
FLR13Y-B Single-core cable
Application
This TPE insulated low-tension automotive cable is used in motorcycles and other motor vehicles for starting ,charging,lighting,signal and instrument panel circuits.
Construction
Conductor: Cu-ETP1 bare according to DIN EN 13602
Insulation: TPE-E
Standard: ISO 6722 Class D
Special properties: Limited resistance to hydrolysis
Technical Parameters: Operating temperature: –40°C to +150°C
Conductor Construction |
Insulation |
Cable |
|||||
Nominal cross- section | No. and Dia. of Wires | Diameter of Conductor max. | Electrical resistance at 20°C max. |
Nominal thickness | Overall Diameter Min. | Overall Diameter Max. | Weight approx. |
mm2 | No./mm | mm | mΩ/m | mm | mm | mm | kg/km |
1x 0.35 | 12/0.21 | 0.9 | 52.0 | 0.20 | 1.2 | 1.4 | 5 |
1x 0. 5 | 16/0.21 | 1.0 | 37.1 | 0.22 | 1.4 | 1.6 | 6 |
1x 0. 75 | 24/0.21 | 1.2 | 24.7 | 0.24 | 1.7 | 1.9 | 9 |
1x1 | 32/0.21 | 1.35 | 18.5 | 0.24 | 1.9 | 2.1 | 12 |
1x 1.5 | 30/0.26 | 1.7 | 12.7 | 0.24 | 2.2 | 2.4 | 16 |
1x 2 | 30/0.31 | 2.0 | 9.42 | 0.28 | 2.5 | 2.8 | 23 |
1x 2.5 | 50/0.26 | 2.2 | 7.6 | 0.28 | 3.7 | 3.0 | 26 |
1x4 | 56/0.31 | 2.75 | 4.71 | 0.32 | 3.4 | 3.7 | 41 |
1x6 | 84/0.31 | 3.3 | 3.14 | 0.32 | 4.0 | 4.3 | 60 |
Note: Other configurations, sizes, colors and length not specified herein are available upon request.