Automotive Cable | |||
Germany Standard | Japanese Standard | American Standard | more |
Automotive Cable
Germany Standard
Single-core cable
FLR7Y-A
Application
This ETFE insulated low-tension automotive cable is used in motorcycles and other motor vehicles for starting ,charging,lighting,signal and instrument panel circuits.
Construction:
Conductor: Cu-ETP1 bare/tinned according to DIN EN 13602
Insulation:
ETFE
Standard:
ISO 6722 Class E
Special properties:
Highly resistant against acids,lyes,petrol and diesel/Excellent chmical resistance/Good mechanical & thermal properties
Technical Parameters:
Operating temperature: –45°C to +180°C
Conductor Construction |
Insulation |
Cable |
|||||
Nominal cross- section | No. and Dia. of Wires | Diameter of Conductor max. | Electrical resistance at 20°C bare/tinned max. |
Nominal thickness | Overall Diameter Min. | Overall Diameter Max. | Weight approx. |
mm2 | No./mm | (mm) | mΩ/m | (mm) | mm | mm | kg/km |
1x0.35 | 7/0.23 | 0.8 | 52/53.5 | 0.20 | 1.2 | 1.3 | 5 |
1x0.5 | 19/0.19 | 1.0 | 37.1/38.2 | 0.22 | 1.4 | 1.6 | 6 |
1x0.75 | 19/0.23 | 1.2 | 24.7/25.4 | 0.24 | 1.7 | 1.9 | 9 |
1x1 | 19/0.26 | 1.35 | 18.5/19.1 | 0.24 | 1.9 | 2.1 | 11 |
1x1.5 | 19/0.32 | 1.7 | 12.7/13.0 | 0.24 | 2.2 | 2.4 | 17 |
1x2.5 | 19/0.41 | 2.2 | 7.6/7.82 | 0.28 | 2.7 | 3.0 | 25 |
Note: Other configurations, sizes, colors and length not specified herein are available upon request.