CCL-FC-MLA-B-C×D-E-F-G-H×I-J-K-L | |
A: Loose tube diameter | |
B=2.1mm, C=2.5mm, D=2.8mm, E=3.0mm, F=3.2mm | |
B: Fiber type | |
0=Fiber and copper conductors in cable 4=50/125 multi-mode fi ber (OM3) per ITU-T G.651 5=50/125 multi-mode fi ber (OM2) per ITU-T G.651 6=62.5/125 multi-mode fi ber (OM1) per ITU-T G.651 7=NZDS SM fi ber per ITU-T G.656. 8=NZDS SM fi ber per ITU-T G.655. 9=Standard SM fi ber per ITU-T G.652.D Ended with R=Ribbon type fi ber ( Ex: 9R= SM fi ber per G.652.D ribbon type ) |
|
C: No. of tubes: | |
1 to 36 | |
D: No. of fi bers per tubes: | |
2 to 12 | |
E: Central member | |
S=Solid steel, SR=Stranded steel, F=Fiber Reinforced Plastic (FRP) | |
F: Inner jacket options | |
2Y=PE, Y=PVC, H=LSZH | |
G: Armour options | |
Blank=No armour, T=Corrugated steel tape armour, W=Steel wire armour B=Bronze armour, D=Fiber glass armour; TW= Steel tape + Steel wire armour | |
H: Jacket material options | |
2Y=PE, Y=PVC, H=LSZH, 11Y=PU, A=Aluminium moisture barrier, T=Anti-termite protection | |
I: Water-blocking options for cable core | |
X=No water-blocking; J= Water blocking gel in tubes; JD=Water-blocking gel in tubes + dry water blocking in cable core interstices; JJ= Water-blocking gel in tubes and cable core interstices. | |
J: Water-blocking options for cables with more than one jacket | |
X=No water-blocking, J= Water blocking gel between jackets; D=Dry water-blocking between cable jackets; | |
K: Strength member options | |
A=Aramid yarn, AG=Aramid yarn and fi berglass yarn, G=Fiberlass yarn | |
L: General options | |
SS=Fig-8 self-supporting UW=Under Water |
CCL-FC-MLA-B-C-D-E-F-G-H-I-J-K-L-M- ADSS | |
A: Loose tube diameter | |
B=2.1mm, C=2.5mm, D=2.8mm, E=3.0mm, F=3.2mm | |
B: Fiber type | |
0=Fiber and copper conductors in cable 4=50/125 multi-mode fi ber(OM3) 5=50/125 multi-mode fi ber(OM2) 6=50/125 multi-mode fi ber(OM1) 7=NZDS SM fi ber per G.656. 8=NZDS SM fi ber per G.655. 9=Standard SM fi ber per G.652.D Ended with R=Ribbon type fi ber ( Ex: 9R= SM fi ber per G.652.D ribbon type ) |
|
C: No. of tubes: | |
01 to 36 | |
D: No. of fi bers per tubes: | |
02 to 12 | |
E: Central member | |
S=Solid steel, SR=Stranded steel, F=Dielectric(FRP) | |
F: Inner jacket options | |
2Y=PE, Y=PVC, H=LSZH | |
G: Armour options | |
T=Corrugated steel tape armour, B=Bronze, W=Steel wire Armour, WB= Steel Wire | |
Braid H: Jacket material options |
|
2Y=PE, AT= Anti-tracking | |
I: Water-blocking options for cable core | |
X=No water-blocking; J= Water blocking gel in tubes; JD=Water-blocking gel in tubes + dry water blocking in cable core interstices; JJ= Water-blocking gel in tubes and cable core interstices. | |
J: Water-blocking options for cables with more than one jacket | |
X=No water-blocking, J= Water blocking gel between jackets; | |
K: Strength member options | |
A=Aramid yarn, AG=Aramid yarn and glass yarn, G=Glass yarn | |
L: Span Length | |
M: Voltage Rating |
CCL-FC-A-B-C-D-E-OPGW |
|
A: Fiber type | |
0=Fiber and copper conductors in cable 4=50/125 multi-mode fi ber(OM3) 5=50/125 multi-mode fi ber(OM2) 6=50/125 multi-mode fi ber(OM1) 7=NZDS SM fi ber per G.656. 8=NZDS SM fi ber per G.655. 9=Standard SM fi ber per G.652.D |
|
B: No. of steel tubes: | |
01 to 3 | |
C: No. of fi bers per tubes: | |
02 to 12 | |
D: Cross Sectional Area | |
35=35mm2; 50=50mm2; 70=70mm2; 90=90 mm2; 130=130mm2 | |
E: Rated Voltage | |
66=66KV; 115=115kV; 150=150kV; 250=250kV; 275=275kV; 380=380kV; 500=500kV |