Rolling Stock Cables | |||||||||||||||
|
Rolling Stock Cables
RSE/STD/024 PART 6
RSE/STD/024 Part 6 Rolling Stock CableVoltage |
Cable Type |
Construction |
Number of Cores |
Cross Sectional |
Design Standard |
Fire Standard |
Single Core, unsheathed |
CU/EM 104 EVA |
1C |
0.5mm2-4mm2, 19/37 stranding |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
|
Single Core, unsheathed |
CU/EM 104 EVA |
1C |
0.5mm2-10mm2, Class 5 stranding |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
|
Single Core, unsheathed |
CU/EM 104 EVA |
1C |
1.0mm2-6.0mm2, Class 5 stranding |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
|
Multicore, with jacketType Ⅶ |
CU/EI 104 EPR/EM 104 EVA |
12/42C |
1.0mm2-1.5mm2, Class 5 stranding |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
|
Multicore, with jacket Type Ⅻ |
CU/EI 104 EPR/EM 104 EVA |
12/42C |
1.0mm2-1.5mm2, Class 5 stranding |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
|
Multipair, with jacket screened |
CU/EI 104 EPR/CUTO/EM 104 EVA |
1,2,3 Prs |
0.5mm2-1.0mm2, Class 5 stranding |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
|
Multipair, with jacket screened |
CU/EI 104 EPR/CUTO/EM 104 EVA |
1,2,3,4 Prs |
0.5mm2-1.0mm2, Class 5 stranding |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
|
Single Core, unsheathed |
CU/EM 104 EVA |
1C |
0.5mm2-4mm2, 19/37 strand |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
|
Single Core, unsheathed |
CU/EM 104 EVA |
1C |
0.75mm2-300mm2, Class 5 stranding |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
|
Single Core, unsheathed |
CU/EM 104 EVA |
1C |
50mm2-185mm2, Class 5 stranding |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
|
Multicore, with jacket |
CU/EI 104 EPR/EM 104 EVA |
10/20C |
2.5mm2-4mm2, Class 5 stranding |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
|
Singlepair, with jacket screened |
CU/EI 104 EPR/CUTO/EM 104 EVA |
1 Prs |
1.0mm2, Class 5 stranding |
RSE/STD/024 Part 6 |
IEC 332-3C IEC 754 IEC1034 |
300/500V Singlecore RSE/STD/024 Part 6 Rolling StockType Ⅳ Cable, unsheathed
Cross- sectional Area |
0.5mm2-4mm2 |
Voltage rating |
300/500V |
Conductor |
Flexible Stranded Tinned Copper |
Number of cores |
1 |
Conductor class |
19/37 AWG stranding |
Insulation |
Cross linked EPR rubber type EI 107, Reduced Wall |
Fire standard |
IEC 332-3C,IEC754;IEC1034-1/2 |
No. of Cores |
Cross Sectional Area (mm2) |
Number and Nominal Diameter of Strands (mm) |
Voltage Rating (V) |
Nominal Overall (mm) |
Nominal Weight (kg/km) |
singlecore |
0.5 |
19/0.18 |
300/500 |
1.34 |
5.4 |
singlecore |
0.75 |
37/0.16 |
300/500 |
1.56 |
8.0 |
singlecore |
1.0 |
37/0.18 |
300/500 |
1.69 |
9.9 |
singlecore |
1.5 |
37/0.23 |
300/500 |
2.07 |
15.7 |
singlecore |
2.5 |
37/0.3 |
300/500 |
2.66 |
26.8 |
singlecore |
4.0 |
37/0.37 |
300/500 |
3.32 |
41.1 |
300/500V Singlecore RSE/STD/024 Part 6 Rolling Stock Type Ⅴ Cable, unsheathed
Cross- sectional Area |
0.5mm2-10mm2 |
Voltage rating |
300/500V |
Conductor |
Flexible Stranded Tinned Copper |
Number of cores |
1 |
Conductor class |
IEC 60228 Class 5 |
Insulation |
Cross linked EPR rubber type EI 107, Standard Wall |
Fire standard |
IEC 332-3C,IEC754;IEC1034-1/2 |
No. of Cores |
Cross Sectional Area (mm2) |
Number and Nominal Diameter of Strands (mm) |
Voltage Rating (V) |
Nominal Overall (mm) |
Nominal Weight (kg/km) |
singlecore |
0.5 |
16/0.2 |
300/500 |
2.32 |
9.6 |
singlecore |
0.75 |
74/0.2 |
300/500 |
2.53 |
12.4 |
singlecore |
1.0 |
32/0.2 |
300/500 |
2.71 |
15.1 |
singlecore |
1.5 |
30/0.25 |
300/500 |
3.23 |
21.9 |
singlecore |
2.5 |
50/0.25 |
300/500 |
3.7 |
33.5 |
singlecore |
4.0 |
56/0.3 |
300/500 |
4.5 |
50.0 |
singlecore |
6.0 |
84/0.3 |
300/500 |
5.09 |
74.6 |
singlecore |
10.0 |
80/0.4 |
300/500 |
6.3 |
122.6 |
300/500V Single Core RSE/STD/024 Part 6 Rolling Stock Type Ⅺ screened Cable
Cross- sectional Area |
1.0mm2-6.0mm2 |
Voltage rating |
300/500V |
Conductor |
Flexible Stranded Tinned Copper |
Number of cores |
1 |
Conductor class |
IEC 60228 Class 5 |
Insulation |
Cross linked EPR rubber type EI 107, Standard Wall |
Fire standard |
IEC 332-3C,IEC754;IEC1034-1/2 |
No. of Cores |
Cross Sectional Area (mm2) |
Number and Nominal Diameter of Strands (mm) |
Voltage Rating (V) |
Nominal Overall (mm) |
Nominal Weight (kg/km) |
Singlecore |
1.0 |
32/0.2 |
300/500 |
3.3 |
19.2 |
Singlecore |
1.5 |
30/0.25 |
300/500 |
3.7 |
26.3 |
Singlecore |
2.5 |
50/0.25 |
300/500 |
4.16 |
37.8 |
Singlecore |
4.0 |
56/0.3 |
300/500 |
4.95 |
56.6 |
Singlecore |
6.0 |
84/0.3 |
300/500 |
5.55 |
80.4 |
300/500V Multicore RSE/STD/024 Part 6 Rolling Stock Type Ⅶ Cable, with jacket
Cross- sectional Area |
1.0mm2-1.5mm2 |
Voltage rating |
300/500V |
Conductor |
Flexible Stranded Tinned Copper |
Number of cores |
12-42 |
Conductor class |
IEC 60228 Class 5 |
Insulation |
Cross linked EPR rubber type EI 107, Standard Wall |
Jacket |
Cross linked EVA rubber type EM 104 |
Fire standard |
IEC 332-3C,IEC754;IEC1034-1/2 |
No. of Cores
|
Cross Sectional Area (mm2) |
Number and Nominal Diameter of Strands (mm) |
Voltage Rating (V) |
Nominal Overall (mm) |
Nominal Weight (kg/km) |
12 Core |
1.0 |
32/0.2 |
30/50 |
20.25 |
309.0 |
42 Core |
1.5 |
30/0.25 |
30/50 |
38.35 |
1661.0 |
300/500V Multicore RSE/STD/024 Part 6 Rolling Stock Type Ⅻ Cable, with jacket
Cross- sectional Area |
1.0mm2-1.5mm2 |
Voltage rating |
300/500V |
Conductor |
Flexible Stranded Tinned Copper |
Number of cores |
12-42 |
Conductor class |
IEC 60228 Class 5 |
Insulation |
Cross linked EPR rubber type EI 107,Standard Wall |
Jacket |
Cross linked EVA rubber type EMI 104 |
Fire standard |
IEC 332-3C,IEC754;IEC1034-1/2 |
No. of Cores |
Cross Sectional Area (mm2) |
Number and Nominal Diameter of Strands (mm) |
Voltage Rating (V) |
Nominal Overall (mm) |
Nominal Weight (kg/km) |
12 Core |
1.0 |
32/0.2 |
300/500 |
20.3 |
309.0 |
42 Core |
1.5 |
30/0.25 |
300/500 |
38.4 |
1661.0 |